Mon–Sat, 09:00–18:00 (GMT+8)Export to 40+ countries
Xucheng Packaging

Quality control and certifications

What we measure, how often, and which document proves it. Certificates are issued against your batch number, and originals are available on request.

Inspection plan

Every batch is measured before it ships

A certificate of analysis travels with each shipment, referencing the batch on your packing list. If a property is critical to your process, tell us and we will add it to the report.

Quality-control room with bench-top test instruments and a rack of PVC sheet samples
Thickness, clarity, resistivity and shrinkage are checked in-house; flame and migration testing goes to an accredited lab
Inspection and test plan
PropertyMethod FrequencySpecification
ThicknessDigital micrometer, 5 points across web widthEvery roll±0.02 mm / ±5%
Light transmissionHaze meter per ASTM D1003Every batch, clear grades≥88%
Surface resistanceMegohmmeter per ANSI/ESD S11.11Every batch, AS grades10⁶ – 10¹⁰ Ω
Flame ratingUL94 vertical burn, third-party labPer formulation and gaugeV-0 or V-2
Shrinkage100 °C / 10 min oven testEvery batch, film grades≤3 – 5%
ColorSpectrophotometer against approved plaqueEvery batch, custom colorΔE ≤1.0
Tensile strengthASTM D882 / ISO 527Per formulation45 – 55 MPa
MigrationAccredited lab, EU 10/2011 / FDAPer formulation, food gradesWithin limits
Certifications

What each document covers

ISO 9001

Quality management system covering order handling, inspection and traceability.

ISO 14001

Environmental management at our partner mills.

SGS test reports

Third-party verification of mechanical and physical properties.

RoHS

Restriction of hazardous substances, issued per formulation.

REACH SVHC

Substances of very high concern declaration for EU shipments.

FDA food contact

21 CFR compliance statements for food-grade material.

EU 10/2011

Plastic food-contact regulation, with migration test data.

UL94 V-0

Flame classification certified at the thickness you order.

If something is wrong

Claims are settled on evidence, not argument

Send photographs, the batch number and your measurement within 30 days of arrival. We re-test our retained sample from the same batch. If the material is out of specification we replace it or credit it, and we cover the freight on the replacement.

Micrometer caliper closed on the edge of a rigid PVC sheet during batch inspection
Retained samples are measured again if you raise a claim

Send your specification, get a quote in one business day

Thickness, width, quantity and destination port are enough to start. Free samples on request.

Request a quote →